Medium

Available on

Apple Android Windows

Gas Appliances and Piping: Access to Suspended Gas Appliances Mobile App

The specifications in the Gas Appliances and Piping: Access to Suspended Gas Appliances mobile app are a supplement to the International Fuel Gas Code and in some cases these specifications differ from the provisions of the foregoing standard. These differences are necessitated by experience based on local conditions and are intended to further ensure that the customer will be provided with safe and efficient operation of their gas appliances. The inspection of gas installations is a cooperative effort by the local code enforcement official and the natural gas supplier. The app covers Access to Suspended Gas Appliances including fixed platforms, stairways and Mobile Stands or Scaffolds. GoCanvas allows you to auto fill your app with information from a reference file.

  • Lendlease
  • The Cooperative
  • PG&E
  • Toys R Us
  • Red Bull
  • Mirvac

Want to learn more about GoCanvas?

Request a Demo

Take a peek inside the Gas Appliances and Piping: Access to Suspended Gas Appliances Mobile App

Included Features

Our App Builder gives you the power to easily add and remove the ones you want. {{controller.show_all ? 'See included features.' : 'See more features.'}}

  • {{data.title}}

Included Fields

Customize to add, remove, or edit any of the fields below.

  • Ico statictext

    Fixed platforms should comply with OSHA Standard 1910.

  • Ico checkbox

    Rigid guard rails shall be installed no less than 36 inches and no more than 42 inches at all op...

  • Ico checkbox

    A 4 inch toeboard should be provided around the edge of the platform.

  • Ico checkbox

    A wire screen of No.

  • Ico checkbox

    Wooden railings and posts shall be at least 2 inch x 4 inch stock with posts spaced not more tha...

  • Ico checkbox

    Pipe railings and posts should be at least 1-1/2 inches nominal diameter with posts spaced not m...

  • Ico checkbox

    Structural steel railings and posts should be 2 inches x 2 inches x 3/8 inch angles or other met...

  • Ico statictext

    Stairways should be built in accordance with OSHA Standard 1910.

  • Ico checkbox

    The angle of the stairway should be between 30 and 50 degrees with the horizontal.

  • Ico checkbox

    The minimum tread width should be 22 inches.

  • Ico checkbox

    Treads less than 9 inches deep should have an open riser as a preferred design.

  • Ico checkbox

    Railings should be provided on the open sides not more than 34 inches nor less than 30 inches ab...

  • Ico checkbox

    Vertical clearance above an overhead stair tread to an overhead obstruction shall be at least 7...

  • Ico statictext

    Manually propelled mobile stands or scaffolds should be built and used in accordance with OSHA St...

  • Ico checkbox

    The maximum work level height should not exceed four times the minimum or least base dimension o...

  • Ico checkbox

    The platform width for any work level should not be less than 36 inches as a preferred design.

  • Ico checkbox

    All work levels 10 ft.

  • Ico checkbox

    All work levels should have a guardrail of 2 inch x 4 inch nominal lumber or the equivalent inst...

  • Ico checkbox

    Steps should have a minimum width of 16 inches.

  • Ico checkbox

    Stairways having more than a 60 inch rise or 5 steps should be equipped with a handrail at least...

  • Ico checkbox

    Fixed ladders should comply with Section 1.

  • ...and More!

Related Construction, Repair & Improvement Apps... and they're all free for GoCanvas subscribers!

App Name

Propane Safety: System Safety

After using the Propane Safety: System Safety mobile app, please take a few minutes more to share it with your family. It’...

App Name

Combustion Appliance Safety and Effic...

The Combustion Appliance Safety and Efficiency Testing mobile app summarizes the inspection and testing of combustion appl...

App Name

Gas Appliances and Piping: Forced War...

The specifications in the Gas Appliances and Piping: Forced Warm Air Heating Systems mobile app are a supplement to the In...

App Name

Gas Appliances and Piping: Ladders

The specifications in the Gas Appliances and Piping: Ladders mobile app are a supplement to the International Fuel Gas Cod...

App Name

Gas Appliances and Piping: Installati...

The specifications in the Gas Appliances and Piping: Installation Practices General Guidelines mobile app are a supplement...

App Name

Interim and Final Gas Checklists

The Interim and Final Gas Checklists mobile app provides separate checklists for the Interim Gas Checklist and the Final G...

App Name

Propane Safety: Maintenance Record

After using the Propane Safety: Maintenance Record mobile app, please take a few minutes more to share it with your family...

App Name

Recommended Procedure for Safety Insp...

The Recommended Procedure for Safety Inspection of Existing Gas Appliances mobile app includes procedures intended as a gu...