Medium

Available on

Apple Android Windows

Water Main Construction Checklist Mobile App

The Water Main Construction Checklist takes you through safety and health compliance issues that must be met prior to passing inspection. The inspection checklist covers: Water and Sewer, Water Mains, Tracer Wires, Fittings, Hydrants, Valves, Loops and Tie Ins, Mortar Joints, Hazard Communication, Shut Downs, Backflow Prevention, Water Services, Testing and Disinfection and Tapping Sleeve and Valves.

This mobile app is designed to be generic in content and may not include all requirements for your particular installation. It can easily be customized to meet specific requirements for city, county and state water treatment regulations to ensure you meet safety and health standards.

Come check out even more of our mobile apps for water utilities.

  • Lendlease
  • The Cooperative
  • PG&E
  • oxy
  • Red Bull
  • Mirvac

Want to learn more about GoCanvas?

Request a Demo

Take a peek inside the Water Main Construction Checklist Mobile App

Included Features

Our App Builder gives you the power to easily add and remove the ones you want. {{controller.show_all ? 'See included features.' : 'See more features.'}}

  • {{data.title}}

Included Fields

Customize to add, remove, or edit any of the fields below.

  • Ico checkbox

    Should design profile be modified based on actual depth of existing utilities and placement

  • Ico checkbox

    Any obstacles or proposed changes to the approved plans that arise during construction need to be...

  • Ico checkbox

    Bore pit to be of sufficient dimension to accommodate entry of pipe

  • Ico checkbox

    Bore depth to be logged by contractor at 25’ intervals

  • Ico checkbox

    DI pipe poly wrapped per AWWA standards

  • Ico checkbox

    Inspect poly wrap for defects

  • Ico checkbox

    Back fill compacted to 95% or better using materials and methods to protect poly wrap

  • Ico checkbox

    Verify how pressure testing and disinfection will be completed relative to construction sequence ...

  • Ico checkbox

    tracer wire taped to main for laid pipe, 2 taped to main for bored pipe per the current LSP.

  • Ico checkbox

    Wire type to follow current LSP or Spec.

  • Ico checkbox

    Splices to be made with water tight direct bury connectors and a knot tied in the wire to keep te...

  • Ico checkbox

    Wire to be brought up on the outside of all main valves and inserted through a ½” hole 8” from th...

  • Ico checkbox

    When a main valve is located farther than 10’ from a hydrant a Valvco termination box is to be us...

  • Ico checkbox

    All tracer wire installed is to be tested for continuity along entire project

  • Ico checkbox

    Fittings double wrapped at least 1’ past glands

  • Ico checkbox

    Fittings fully encased with poly and taped

  • Ico checkbox

    Fittings of the type approved for use by City.

  • Ico checkbox

    Retainer glands shall be new and appropriate for the pipe materials being used

  • Ico checkbox

    Review field modifications that require use of retainer glands

  • Ico checkbox

    All poured blocking shall be formed with no concrete underneath or over the fitting

  • Ico checkbox

    Where undisturbed soil is present, fitting may be dry blocked

  • Ico checkbox

    Pipe marked and inserted to home

  • Ico checkbox

    Gaskets properly seated

  • Ico checkbox

    Fittings properly tightened

  • Ico checkbox

    All blocking shall be made against undisturbed soil

  • Ico checkbox

    Fittings to be inspected for defects

  • Ico checkbox

    Properly cleaned and disinfected prior to installation

  • Ico checkbox

    Consult with Contractor regarding any necessary hydrant configuration or location changes based o...

  • ...and More!

Related Utilities & Energy Apps... and they're all free for GoCanvas subscribers!

App Name

Alteration Polybutylene Re-Pipe Inspe...

The Alteration Polybutylene Re- Pipe Inspection Checklist takes you through compliance issues that must be met prior to pa...

App Name

Excavation and Trenching Competent Pe...

The Excavation and Trenching Competent Person Evaluation is designed to help assist the employer determine if the person h...

App Name

Flood Damaged Homes Action Items for ...

The Flood Damaged Homes Action Items for Contractors takes you through compliance issues that must be met prior to passing...

App Name

Low Pressure Steam Boiler Pre-Inspect...

The Low Pressure Steam Boiler Pre-Inspection Checklist mobile app provides a simple inspection for low pressure vessels an...

App Name

Civil Inspection Final Walk thru Punc...

The Civil Inspection Final Walk thru Punch List mobile app is a standard punch list form to provide uniform inspection. Av...

App Name

Landscape Contractor Punch List

The Landscape Contractor Punch List mobile app is provided primarily for landscape contractors who have not previously wor...

App Name

Product Punch List

The Product Punch List mobile app is a detailed project punch list for contractors. The app covers the following areas: Ge...

App Name

Punch List

The Punch List mobile app is a list of items to be completed or corrected by the contractor. The failure to include any it...

More Information