The Copper Tubing Gas Line Pre Inspection Checklist mobile app is designed to be generic in content and may not include all requirements for your particular installation. The manufacturer’s installation instruction must be adhered to and available to the inspector at the time of the inspection. Be sure you can answer YES to all of the questions before calling for inspection. Failure of the inspection will require a reinspection fee to be paid.

  • Lendlease
  • The Cooperative
  • PG&E
  • Red Bull
  • Mirvac

Want to learn more about GoCanvas?

Request a Demo

Take a peek inside the Copper Tubing Gas Line Pre Inspection Checklist Mobile App

Included Features

Our App Builder gives you the power to easily add and remove the ones you want. {{controller.show_all ? 'See included features.' : 'See more features.'}}

  • {{data.title}}

Included Fields

Customize to add, remove, or edit any of the fields below.

  • Ico checkbox

    ) Gas piping shall be designed for natural gas and acceptable for LP gas.

  • Ico checkbox

    ) All materials used shall be new and free from defects and internal obstructions.

  • Ico checkbox

    a) an annealed type, Grade K or L, conforming to the Standard specification for Seamless Copper w...

  • Ico checkbox

    b) shall comply with the standard Specification for Seamless Copper Tube for Air Conditioning and...

  • Ico checkbox

    c) shall be internally tinned.

  • Ico checkbox

    a) made only with bending equipment and procedures especially intended for that purpose;

  • Ico checkbox

    b) smooth and free from buckling, cracks, or other evidence of mechanical damage;

  • Ico checkbox

    c) not bent through an arc of more than 90 degrees; and

  • Ico checkbox

    d) have an inside radius of not less than 6 times the outside diameter of the pipe.

  • Ico checkbox

    (2) Fittings for copper tubing gas lines shall be of brass containing not more than 75 percent co...

  • Ico checkbox

    ) Gas piping shall be sized so that the pressure drop to any appliance inlet connection, when all...

  • Ico checkbox

    ) The system shall be design for a pressure not exceeding ½ PSI and not less than 1/4 PSI.

  • Ico checkbox

    ) The natural gas supply connection shall be not less than the size of the gas piping and not sma...

  • Ico checkbox

    ) Connections shall not be located beneath an exit door.

  • Ico checkbox

    ) Connection shall be rigidly anchored to a structural member within 6 inches of the supply conne...

  • Ico checkbox

    Joints shall not be located in any floor, wall, partition or similar concealed space.

  • Ico checkbox

    Gas piping shall be supported by metal straps (not galvanized) that have the equivalent protectio...

  • Ico checkbox

    All penetrations into the home shall be sealed.

  • Ico checkbox

    When piping is installed in more than one section, the crossover connection shall:

  • Ico checkbox

    ) be readily accessible from the exterior of the home.

  • Ico checkbox

    2) be made by the use of either:

  • Ico checkbox

    a) connector(s) listed for exterior use with a shutoff valve upstream of the connection;

  • Ico checkbox

    b) direct plumbing with a shutoff valve upstream of the connection;

  • Ico checkbox

    c) listed quick disconnect which shall be designed to provide a positive seal on the supply side.

  • Ico statictext

    The gas line shall be bonded to the frame of the home by the use of:

  • Ico checkbox

    1) solderless type grounding terminal with a star washer bolted to the chassis;

  • Ico checkbox

    2) grounding strap attached to the gas piping; and

  • Ico checkbox

    ) a bonding conductor of #8 copper wire.

  • ...and More!

Related Construction, Repair & Improvement Apps... and they're all free for GoCanvas subscribers!

App Name

Annual Servicing For Gas Appliances 

The Authority, who regulates the installation of Gas equipment, would advise homeowners with the heating season at hand th...

App Name

Finished Water Storage Tank Inspectio...

This Finished Water Storage Tank Inspection Cleaning Checklist Mobile App allows users to fill out one checklist per stora...

App Name

Copper Water Line Re-Pipe Inspection ...

The Copper Water Line Re-Pipe Inspection Checklist mobile app is to be used as a general checklist’ it is not inclusive of...

App Name

Commercial Buildings Saving Energy: C...

The Commercial Buildings Saving Energy: Chilled Water System Checklist mobile app includes a checklist specific to commerc...

App Name

Consumers Energy Residential HVAC Inc...

The Consumers Energy Residential HVAC Incentive Form Mobile App is used to complete the Consumers Energy Residential HVAC ...

App Name

Commercial Buildings Saving Energy: P...

The Commercial Buildings Saving Energy: Plug Loads Checklist mobile app includes a checklist specific to commercial buildi...

App Name

Wall Furnace Installation Checklist

Wall furnaces are heating systems that are great for heating small rooms. They are installed without any ductwork involved...

App Name

Hydronic Heating – Homeowner Service ...

The Hydronic Heating – Homeowner Service Checklist mobile app is a simple way for homeowners to evaluate Hydronic Heating ...

More Information