Dip Tanks Containing Flammable or Combustible Liquids Checklist Mobile App

The Dip Tanks Containing Flammable or Combustible Liquids Checklist mobile app covers some of the regulations issued by U.S. Department of Labor - OSHA the General Industry standard 1910.125. The Uniform Fire Code has adopted the model code of the Building Officials and Code Administrators International, Inc. known as the “BOCA National Fire Prevention Code/1996" by reference. The checklist applies to dip tanks in educational buildings that use flammable or combustible liquids. It also applies to any vapor area containing dangerous quantities of flammable vapors in the vicinity of dip tanks, their drain boards or associated drying, conveying or other equipment, during operation or shutdown periods.

  • Lendlease
  • The Cooperative
  • PG&E
  • Red Bull
  • Mirvac

Want to learn more about GoCanvas?

Request a Demo

Take a peek inside the Dip Tanks Containing Flammable or Combustible Liquids Checklist Mobile App

Included Features

Our App Builder gives you the power to easily add and remove the ones you want. {{controller.show_all ? 'See included features.' : 'See more features.'}}

  • {{data.title}}

Included Fields

Customize to add, remove, or edit any of the fields below.

  • Ico checkbox

    In educational buildings, are dip tanks used only in a room designed for the purpose, protected ...

  • Ico checkbox

    Are dip tanks, including any drainboards, constructed of noncombustible materials?

  • Ico checkbox

    For dip tanks over 150 gallons in capacity or 10 square feet in liquid surface area, is there a ...

  • Ico checkbox

    Is the overflow pipe at least 3 inches in diameter?

  • Ico checkbox

    Are all piping connections on the dip tank easily accessible for inspection and cleaning?

  • Ico checkbox

    Is the bottom of the overflow connection not less than 6 inches from the top of the dip tank?

  • Ico checkbox

    If the dip tank is over 500 gallons in capacity, is it equipped with a bottom drain?

  • Ico statictext

    Note: Bottom drains are not required if (i) the dip tank is equipped with an automatic closing co...

  • Ico checkbox

    Will the required bottom drain operate during a fire?

  • Ico checkbox

    Is the required bottom drain properly trapped and discharged to a safe location outside?

  • Ico checkbox

    Are required bottom drains automatically and manually arranged to quickly drain in the event of ...

  • Ico checkbox

    Is manual operation of required bottom drains available at a safely accessible location?

  • Ico checkbox

    If required bottom drains do not operate by gravity flow, is an automatic pump provided?

  • Ico checkbox

    Is the temperature of the liquid in each dip tank maintained below the liquid’s boiling point an...

  • Ico checkbox

    Are open flames, spark production devices, or heated surfaces hot enough to ignite vapors absent...

  • Ico checkbox

    In each vapor area and any adjacent area, do all electrical wiring and equipment conform to appl...

  • Ico checkbox

    Are any portable containers used to add liquid to the tank electrically bonded to the tank and p...

  • Ico checkbox

    Are heating systems used in a drying operations installed in accordance with NFPA 86A-1969 and p...

  • Ico checkbox

    Do these heating systems shut down automatically if any ventilating fan fails to maintain adequa...

  • Ico multiline

    Comments/Corrective Action

  • Ico checkbox

    Are all vapor areas free of combustible debris and as free as possible from combustible stock?

  • Ico checkbox

    Are rags and other material contaminated with liquids or coating operations placed in approved w...

  • Ico statictext

    Note: Metal waste cans must have self-closing lids.

  • Ico checkbox

    Are the contents of these waste cans properly disposed of at least once daily at the end of the ...

  • Ico checkbox

    Are "No Smoking” signs in large letters on a contrasting color background conspicuously posted i...

  • Ico multiline

    Comments/Corrective Action

  • Ico checkbox

    Are suitable manual and automatic fire extinguishers available for areas in the vicinity of dip ...

  • Ico statictext

    Note: Consult you local fire official for assistance.

  • ...and More!

Related Government & NGO Apps... and they're all free for GoCanvas subscribers!

App Name

Flammable Materials Work Procedures a...

Employers must develop work procedures for the use and storage of flammable materials and ensure workers are trained on th...

App Name

Chemical Safety: Compressed Gases Che...

Compressed gases can become dangerous projectiles if they fall and compromise safety. The Chemical Safety: Compressed Gase...

App Name

University Lab Inspection Form

The Environmental Health and Safety Office (EH&S) conducts annual inspections intended to assist supervisors and princ...

App Name

Flammable and Combustible Liquid Storage

The purpose of the Flammable and Combustible Liquid Storage mobile app is to provide guidelines to reduce potential exposu...

App Name

Flammable Liquid Storage Audit

The Flammable Liquid Storage Audit app is a self inspection developed for facilities. The app can be completed on a mobile...

App Name

Chemical Safety: Working with Flammab...

The Chemical Safety: Working with Flammable Chemicals Checklist mobile app is designed to assist individuals working with ...

App Name

Self-Inspection Checklist for Flammab...

The Flammable Solvent Inspection Checklist mobile app is designed to be used routinely by operators to ensure utmost safet...

App Name

Flammable and Combustible Liquid Self...

The Flammable and Combustible Liquid Self Inspection Checklist mobile app was designed for storage of flammable or combust...

Related Blog Posts