Medium

Available on

Apple Android Windows

Residential Inspection Guide: Rough Mechanical Inspection Mobile App

The Residential Inspection Guide: Rough Mechanical Inspection mobile app is intended for conventional wood frame residential construction based on the International Residential Code. The purpose of this app is to provide a better understanding of the Rough Mechanical Inspection process and the relationship between the building inspector and the contractor. The information in this app is designed to better prepare residential building projects for inspection. GoCanvas allows you to set the date format in for your apps.

  • Lendlease
  • The Cooperative
  • PG&E
  • Red Bull
  • Mirvac

Want to learn more about GoCanvas?

Request a Demo

Take a peek inside the Residential Inspection Guide: Rough Mechanical Inspection Mobile App

Included Features

Our App Builder gives you the power to easily add and remove the ones you want. {{controller.show_all ? 'See included features.' : 'See more features.'}}

  • {{data.title}}

Included Fields

Customize to add, remove, or edit any of the fields below.

  • Ico checkbox

    Heating and cooling equipment shall be located with respect to building construction and other eq...

  • Ico checkbox

    A secondary drain or auxiliary drain pan shall be required for each cooling or evaporator coil wh...

  • Ico checkbox

    Condensate waste and drain line size shall be not less than ¾-inch internal diameter and shall no...

  • Ico checkbox

    Secondary condensate line to discharge at a point that is readily observed UMC 310.

  • Ico checkbox

    Duct work and diffusers sized per approved plans.

  • Ico checkbox

    Duct work properly supported (flex duct min.

  • Ico checkbox

    Support and secure refrigerant piping within 6’ from the first bend from the compressor and withi...

  • Ico checkbox

    Gas furnaces to be vented by a system designed and constructed to develop a positive flow to conv...

  • Ico checkbox

    Gas furnaces located in garages to have a minimum of 18” from the garage floor to the source of i...

  • Ico checkbox

    Gas furnaces located in garages shall be guarded against damage by being elevated or located behi...

  • Ico checkbox

    Dryer ducts shall not be connected or installed with screws or fasteners that will obstruct air f...

  • Ico checkbox

    Dryer vent terminations shall have back draft dampers except when terminating at a roof.

  • Ico checkbox

    The maximum length of a clothes dryer exhaust duct shall not exceed 14 feet from the dryer locati...

  • Ico checkbox

    Factory built fireplaces shall be installed per the manufacturer’s installation instructions.

  • Ico checkbox

    Factory built fireplaces installed in exterior locations shall be listed for that use.

  • Ico checkbox

    Gas vents (factory-built chimneys) shall have a minimum clearance to combustibles as per the manu...

  • Ico checkbox

    A gas vent passing through a roof shall extend through the roof flashing, roof jack or roof thimb...

  • Ico checkbox

    A Type B or L gas vent shall terminate at least 5 feet in vertical height above the highest conne...

  • Ico checkbox

    Gas vents that are 12 inches or less in size and located not less than 4 feet from a vertical wal...

  • Ico checkbox

    In concealed locations, where a vent is installed through holes or notches in studs, joists, raft...

  • Ico checkbox

    A gas vent shall terminate with a listed cap or listed roof assembly a minimum of 12” from the ro...

  • Ico checkbox

    Venting systems shall be sized and constructed in accordance with or other approved engineering m...

  • Ico checkbox

    Chimneys and gas vents for factory built fireplaces shall be installed per manufacturer’s instruc...

  • Ico checkbox

    Attics containing appliances requiring access shall have an opening and a clear and unobstructed ...

  • Ico checkbox

    A luminaire controlled by a switch located at the required passageway opening and a receptacle ou...

  • ...and More!

Related Construction, Repair & Improvement Apps... and they're all free for GoCanvas subscribers!

App Name

New Customer Form

This new customer form mobile app provides simple new customer forms for service based companies such as dry cleaning, law...

App Name

School Injury Report - Simple Version

If you're a staff member at a school the School Injury Report Mobile App is perfect for collecting key accident/injury inf...

App Name

OSHA - Notice of Alleged Safety Viola...

"OSHA inspections for occupational safety can reveal health hazards and even imminent danger. This mobile app for the comp...

App Name

Parking Citation

The Parking Citation mobile app for police departments and parking services professionals makes it possible to generate ne...

App Name

Natural Gas - Pipeline Survey

The Natural Gas Pipeline Survey mobile app was designed specifically for the natural gas industry. Instead of using paper ...

App Name

VA Dem House Race - Political Canvass...

This VA Dem House Race Political Canvassing Form was developed to be an electronic form of a survey sent out by the Virgin...

App Name

Road Construction and Equipment Tracking

The Road Construction and Equipment Tracking mobile app for construction managers and road crews tracks employee time shee...

App Name

Apparel Retail Form

This handy apparel retail form mobile app was built for a mobile retail sales associate or sales assistant. Great for depa...

More Information


Related Blog Posts