Medium

Available on

Apple Android Windows

Residential Inspection Guide: Rough Electrical Inspection Mobile App

The Residential Inspection Guide: Rough Electrical Inspection mobile app is intended for conventional wood frame residential construction based on the International Residential Code. The purpose of this app is to provide a better understanding of Rough Electrical Inspection process and the relationship between the building inspector and the contractor. The information in this app is not all inclusive and is designed to better prepare residential building projects for inspection. You can create a template with GoCanvas, that then can be used to create a new apps.

  • Lendlease
  • The Cooperative
  • PG&E
  • Toys R Us
  • Red Bull
  • Mirvac

Want to learn more about GoCanvas?

Request a Demo

Take a peek inside the Residential Inspection Guide: Rough Electrical Inspection Mobile App

Included Features

Our App Builder gives you the power to easily add and remove the ones you want. {{controller.show_all ? 'See included features.' : 'See more features.'}}

  • {{data.title}}

Included Fields

Customize to add, remove, or edit any of the fields below.

  • Ico checkbox

    Electrical equipment shall be installed in a neat and workmanlike manner.

  • Ico checkbox

    Old used or damaged material and equipment shall not be used or installed in any work.

  • Ico checkbox

    A single family dwelling service shall have a minimum rating of not less than 100 amperes, 3-wire...

  • Ico checkbox

    The grounding electrode conductor shall be attached to the grounding electrode (UFER) by exotherm...

  • Ico checkbox

    If available, metal underground pipe in contact with the earth a minimum of 10’, metal frame of t...

  • Ico checkbox

    Aluminum electrodes and metal underground gas piping system shall not be used as grounding electr...

  • Ico checkbox

    Equipment grounding conductors shall be isolated from the grounded conductors at a sub main (pane...

  • Ico checkbox

    The minimum working space at the main panel board and any other panel boards shall be no less tha...

  • Ico checkbox

    Unused openings in boxes, enclosures and cabinets shall be effectively closed.

  • Ico checkbox

    The minimum number of circuits serving a countertop for small appliances shall be two 20 amperes.

  • Ico checkbox

    Bathrooms shall have at least one 20-ampere circuit and shall serve no other outlets.

  • Ico checkbox

    Bathrooms shall have at least one outlet within 3’ of the outside edge of the basin.

  • Ico checkbox

    An outlet shall be installed at the front and the back of the dwelling and be accessible at grade...

  • Ico checkbox

    A minimum of one outlet shall be installed at each basement and garage.

  • Ico checkbox

    Hallways of 10’ or more in length shall have a minimum of one outlet.

  • Ico checkbox

    Receptacles shall be installed along the floor line in any wall space so that no point is more th...

  • Ico checkbox

    At least one wall switched lighting outlet shall be installed in every habitable room, hallway, s...

  • Ico checkbox

    All metal boxes shall be grounded by a metal screw or listed device used for no other purpose tha...

  • Ico checkbox

    All equipment grounding conductors installed in a box for a device shall be joined within the box...

  • Ico checkbox

    A minimum of 6” of free conductor shall be available at each switch point, outlet, and junction ...

  • Ico checkbox

    Raceways, cable assemblies, boxes, cabinets and fittings shall be securely fastened in place.

  • Ico checkbox

    Cables and insulated conductors installed in raceways for underground installations shall be list...

  • Ico checkbox

    Nonmetalic-sheathed cable shall be secured by staples, cable ties, straps, hangers or similar fit...

  • Ico checkbox

    Nonmetalic cables shall be secured to each metal cabinet and protected from abrasion.

  • Ico checkbox

    Outlet boxes or outlet box systems used as the sole support of a ceiling-suspended (paddle) fan s...

  • Ico checkbox

    Type IC recessed luminaries shall be permitted to be in contact with combustible materials such a...

  • Ico checkbox

    Interconnected smoke alarms shall be installed in each sleeping area, outside of each sleeping ar...

  • Ico checkbox

    Cables installed through bored holes within 1 ¼” of the face of the studs or other wood framing m...

  • ...and More!

Related Construction, Repair & Improvement Apps... and they're all free for GoCanvas subscribers!

App Name

New Customer Form

This new customer form mobile app provides simple new customer forms for service based companies such as dry cleaning, law...

App Name

School Injury Report - Simple Version

If you're a staff member at a school the School Injury Report Mobile App is perfect for collecting key accident/injury inf...

App Name

OSHA - Notice of Alleged Safety Viola...

"OSHA inspections for occupational safety can reveal health hazards and even imminent danger. This mobile app for the comp...

App Name

Parking Citation

The Parking Citation mobile app for police departments and parking services professionals makes it possible to generate ne...

App Name

Natural Gas - Pipeline Survey

The Natural Gas Pipeline Survey mobile app was designed specifically for the natural gas industry. Instead of using paper ...

App Name

VA Dem House Race - Political Canvass...

This VA Dem House Race Political Canvassing Form was developed to be an electronic form of a survey sent out by the Virgin...

App Name

Road Construction and Equipment Tracking

The Road Construction and Equipment Tracking mobile app for construction managers and road crews tracks employee time shee...

App Name

Apparel Retail Form

This handy apparel retail form mobile app was built for a mobile retail sales associate or sales assistant. Great for depa...

More Information