Medium

Available on

Apple Android Windows

Potable Hot Water Boilers Pre-Inspection Checklist Mobile App

The Potable Hot Water Boilers Pre-Inspection Checklist takes you through compliance issues that must be met prior to passing inspection. This checklist reflects the most common violations field inspectors encounter when performing an inspection on potable hot water boiler installations built to the American Society of Mechanical Engineers (ASME) Heating Boiler Code. It is highly suggested that all boiler industry personnel have access to a current set of applicable codebooks and jurisdiction laws.

  • Lendlease
  • The Cooperative
  • PG&E
  • oxy
  • Red Bull
  • Mirvac

Want to learn more about GoCanvas?

Request a Demo

Take a peek inside the Potable Hot Water Boilers Pre-Inspection Checklist Mobile App

Included Features

Our App Builder gives you the power to easily add and remove the ones you want. {{controller.show_all ? 'See included features.' : 'See more features.'}}

  • {{data.title}}

Included Fields

Customize to add, remove, or edit any of the fields below.

  • Ico statictext

    Mechanical Engineers (ASME) Heating Boiler Code.

  • Ico statictext

    Controls

  • Ico checkbox

    Each individual automatically fired water heater, in addition to the operating control used for n...

  • Ico statictext

    Installation Requirements

  • Ico checkbox

    temperature and pressure safety relief valve or at least one officially rated safety relief valve.

  • Ico checkbox

    No safety relief valve shall be smaller than NPS ¾ inch.

  • Ico checkbox

    The safety relief valve pressure setting shall be less than or equal to the maximum allowable wor...

  • Ico checkbox

    The required relieving capacity in Btu/hr of the safety relief valve shall not be less than the m...

  • Ico checkbox

    Safety relief valves shall be connected to the top of water heaters or directly to a tapped or fl...

  • Ico checkbox

    Safety relief valves shall be installed with their spindles upright and vertical with no horizont...

  • Ico checkbox

    No piping or fitting used to mount the safety relief valve shall be of a nominal pipe size less t...

  • Ico checkbox

    Safety relief valves shall not be connected to an internal pipe in the water heater or a cold wat...

  • Ico checkbox

    No shutoff of any description shall be placed between the safety relief valve and the water heate...

  • Ico checkbox

    When a discharge pipe is used, its internal cross-sectional area shall be not less than the full ...

  • Ico checkbox

    The discharge from safety relief valves shall be so arranged that there will be no danger of scal...

  • Ico checkbox

    The safety relief valve discharge shall be as short and straight as possible and so arranged as t...

  • Ico checkbox

    Water supply shall be introduced into a water heater through an independent water supply connection.

  • Ico checkbox

    connections provided for cleaning, safety relief valves, drain, or temperature gage.

  • Ico checkbox

    Provisions shall be made for the expansion and contraction of hot water mains connected to water ...

  • Ico checkbox

    Each water heater shall have a bottom drain pipe connection fitted with a valve or cock connected...

  • Ico checkbox

    Any discharge piping connected to the bottom drain connection shall be full size to the point of ...

  • Ico checkbox

    Each installed water heater shall have a thermometer so located and connected that it shall be ea...

  • Ico checkbox

    The thermometer shall be so located that it shall at all times indicate the temperature of the wa...

  • Ico statictext

    NOTE: Make certain that all items listed above are in compliance prior to requesting an inspectio...

  • ...and More!

Related Construction, Repair & Improvement Apps... and they're all free for GoCanvas subscribers!

App Name

Low Pressure Steam Boiler Pre-Inspect...

The Low Pressure Steam Boiler Pre-Inspection Checklist takes you through compliance issues that must be met prior to passi...

App Name

Underground Plumbing Inspection Check...

The Underground Plumbing Inspection Checklist mobile app makes it easy to perform underground plumbing inspections using a...

App Name

Alteration Polybutylene Re-Pipe Inspe...

The Alteration Polybutylene Re- Pipe Inspection Checklist takes you through compliance issues that must be met prior to pa...

App Name

Potable Water Heaters Pre-Inspection ...

The Potable Water Heaters Pre-Inspection Checklist takes you through compliance issues that must be met prior to passing i...

App Name

Air Conditioner/ Heat Pump Pre-Inspec...

Looking for an air conditioner/heat pump pre-inspection checklist for your team members to reference while they work? The ...

App Name

High Pressure Boilers Pre-Inspection ...

The High Pressure Boilers Pre- Inspection Checklist takes you through compliance issues that must be met prior to passing ...

App Name

30 Day Punch List Form

The 30 Day Punch List Form mobile app is designed for homeowners to review and inspect their home 30 days after the origin...

App Name

Homeowner Punch List Form

The Homeowner Punch List Form mobile is intended as a guideline for a punch list. Your builder or attorney may have his/he...

More Information