Low Pressure Steam Boiler Pre-Inspection Checklist Mobile App

The Low Pressure Steam Boiler Pre-Inspection Checklist mobile app provides a simple inspection for low pressure vessels and boilers. Inspectors can use the app to ensure the equipment meets pressure vessel code requirements.

Pressure vessel inspectors can use the app to check all areas of boilers and pressure vessels, including the relief valve, water level, maximum allowable working pressure, piping and more. Boiler operators and inspectors can sign off on the completed form electronically and save it for their records.

  • Lendlease
  • The Cooperative
  • PG&E
  • Red Bull
  • Mirvac

Want to learn more about GoCanvas?

Request a Demo

Take a peek inside the Low Pressure Steam Boiler Pre-Inspection Checklist Mobile App

Included Features

Our App Builder gives you the power to easily add and remove the ones you want. {{controller.show_all ? 'See included features.' : 'See more features.'}}

  • {{data.title}}

Included Fields

Customize to add, remove, or edit any of the fields below.

  • Ico statictext

    Notice: This checklist reflects the most common violations our field inspectors encounter when pe...

  • Ico statictext

    Administration and General Requirements

  • Ico checkbox

    Contractors must be registered with the Department of Labor & Industries before installing, and m...

  • Ico checkbox

    Once the installation/reinstallation is complete the owner or user shall not operate the boiler u...

  • Ico checkbox

    A Boiler/Pressure Vessel Installation or Reinstallation Permit form from must be submitted to the...

  • Ico checkbox

    All low-pressure steam boilers shall be constructed, stamped, and installed in conformance with A...

  • Ico checkbox

    The minimum clearance for low pressure steam boilers is determined by the BTU input.

  • Ico checkbox

    All boilers installed or refitted after December 1998, shall be equipped with suitable primary sa...

  • Ico checkbox

    A manually operated remote shutdown switch or circuit breaker should be located outside the boile...

  • Ico checkbox

    The owner/user is responsible for fees.

  • Ico checkbox

    Each steam boiler shall have a steam gage or a compound steam gage connected to its steam space o...

  • Ico checkbox

    The gage shall contain a siphon, or an equivalent device that will develop and maintain a water s...

  • Ico checkbox

    The gage connection to the boiler shall not be less than NPS ¼ inch.

  • Ico checkbox

    The graduated scale on the dial of a low-pressure steam gage shall be not less than 30 psi or mor...

  • Ico checkbox

    Each steam boiler shall have one or more water gage glasses attached to the water column or boile...

  • Ico checkbox

    The lowest visible part of the water gage glass shall be at least 1 inch above the lowest permiss...

  • Ico checkbox

    The minimum size of ferrous or nonferrous pipes connecting a water column to a steam boiler shall...

  • Ico checkbox

    The water column piping shall have a cross or equivalent fitting at every right angle turn to fac...

  • Ico checkbox

    No shutoff valves shall be placed between the steam boiler and water column.

  • Ico checkbox

    The water column drain pipe and valve shall be not less than NPS ¾ inch.

  • Ico checkbox

    Each automatically fired steam boiler shall be protected from over pressure by two-pressure-opera...

  • Ico checkbox

    No shutoff valves shall be placed between the controls and steam boiler.

  • Ico checkbox

    The controls will be protected with a siphon, or an equivalent device that will develop and maint...

  • Ico checkbox

    The control connection to the boiler shall not be less than NPS ¼ inch, if steel or wrought iron ...

  • Ico checkbox

    Each automatically fired steam boiler shall have two automatic low-water fuel cutoff so located a...

  • Ico checkbox

    Fuel cutoffs and water feeding devices embodying a separate chamber shall have a vertical drain p...

  • Ico checkbox

    Safety valves and safety relief valves shall be located in the top or side of the boiler, but in ...

  • Ico checkbox

    Coil or header type boilers shall have the safety valve or safety relief valve located on the ste...

  • ...and More!

Related Construction, Repair & Improvement Apps... and they're all free for GoCanvas subscribers!

App Name

High Pressure Boilers Pre-Inspection ...

The High Pressure Boilers Pre- Inspection Checklist takes you through compliance issues that must be met prior to passing ...

App Name

Air Conditioner/ Heat Pump Pre-Inspec...

Looking for an air conditioner/heat pump pre-inspection checklist for your team members to reference while they work? The ...

App Name

Potable Hot Water Boilers Pre-Inspect...

The Potable Hot Water Boilers Pre-Inspection Checklist takes you through compliance issues that must be met prior to passi...

App Name

Alteration Polybutylene Re-Pipe Inspe...

The Alteration Polybutylene Re- Pipe Inspection Checklist takes you through compliance issues that must be met prior to pa...

App Name

Potable Water Heaters Pre-Inspection ...

The Potable Water Heaters Pre-Inspection Checklist takes you through compliance issues that must be met prior to passing i...

App Name

Underground Plumbing Inspection Check...

The Underground Plumbing Inspection Checklist mobile app makes it easy to perform underground plumbing inspections using a...

App Name

Commercial Punch List

The Commercial Punch List app is intended for property owners of commercial retail estate who don't want to spend money on...

App Name

New Construction Professional Inspec...

The New Construction Professional Inspection Addendum Punch List mobile app allows real estate agents to complete and subm...